New Silver Mini 3

The table that follows summarises the periodic and preventative maintenance jobs required to keep the compressor in an efficient operational state in time.

A brief description of the running hours after which the type of maintenance job is required.

Before performing any jobs within the sound-proof cabinet, ensure that:

- The main line switch is turned off (position “0”)

- The compressor is disconnected from the compressed air system

All the pressure has been released from the compressor and internal pneumatic circuit.

PERIOD Weekly 3 month 1° year 2° year 3° year 4°year 5°year 6°year 7°year 8°year
HOURS OF DUTY   500 2500 5000 7500 10000 12500 15000 17500 20000
GENERAL RECURRING CHECKS                    
Drain the condensate X                  
Check oil level   X X X X X X X X X
Check electric connections   X X X X X X X X X
Check oil/air leaks X X X X X X X X X X
Check condensate into the oil   X X X X X X X X X
Functional check cooling fan   X X X X X X X X X
Functional check suction valve   X X X X X X X X X
Check oil recovery   X X X X X X X X X
Check pressure setting   X X X X X X X X X
AIR/OIL CIRCUIT                    
Replace air filter cartridge     X X X X X X X X
Replace oil filter cartridge   X X X X X X X X X
Replace oil separator filter cartridge   X X X X X X X X X
Oil change   X X X X X X X X X
Cleaning ari/oil radiator     X X X X X X X X
Oil recovery overhaoul       X   X   X   X
Suction valve overhaul       X   X   X   X
Replace hydraulic hoses           X       X
Minimum pressure valve overhaul         X     X    
ELECTRICAL CIRCUIT                    
Check / replace pressure switch / transducer       X   X   X   X
Check / replace solenoid       X   X   X   X
Check / replace temperature probe       X   X   X   X
MAINTENANCE                    
Replace electrical motor bearings         X     X    
Screw unit total overhaul                   X
Replace screw unit seal           X       X
Replace security valve         X     X    

Note! If the compressor is used for more than 3000 hours/year the jobs indicated herewith are to be

performed more often.